The roof deck in an unvented attic must be exceptionally airtight.
Conditioned space attic.
The acceptance of unvented conditioned attics continues to grow among builders and building officials.
Code requirements vary across the country.
Most contractors would never consider installing uninsulated ducts in a vented attic or crawlspace but regularly do in basements and foamed attics.
Low efficiency gas appliances that are prone to spillage or backdrafting are not recommended in this type of application.
An outdoor unit which houses the fan condenser and compressor and an indoor unit which holds the evaporator and fan.
If there is a desire to make that space conditioned to protect stored belongings if moving everything out to air seal and insulate at the attic floor would be a hassle and or if insulating at the attic floor would remove storage space then insulating at the roof line is a better option.
Unvented conditioned attics were quite rare before the 1980s.
So why put an hvac system up in the attic at all.
Is the attic used for a significant amount of storage.
A fundamental requirement of an unvented attic assembly is the use of air impermeable insulation on the underside of the unvented roof to prevent air infiltration and exclude airborne moisture from the attic.
The attic space becomes indirectly conditioned as a result of the air leakage heat transfer and vapor diffusion through the ceiling.
A common idea promoted across the industry is that any heat lost from an uninsulated duct system to a conditioned space isn t truly lost and has no effect on energy consumption.
Among the early promoters of conditioned attics was joe lstiburek a principal of the building science corporation.
The air handling unit is located in a conditioned basement.
The irc has permitted unvented conditioned attics since 2006 with certain requirements.
Making the attic a conditioned space taking the building envelope to the roof is a good approach and will save energy another approach is to use radiant coated deck sheathing seal all ceiling attic penetrations and blow in r 60 insulation as it will cost less than spray foam and should give at least the same energy efficiency to the home.
Ducts in conditioned space details figure 1 vented and unconditioned attic.
Lstiburek s enthusiasm was rooted in his desire to bring attic ductwork inside a home s thermal envelope.
Well mainly it s a way to save space.
In unfinished attic spaces insulate between and over the floor joists to seal off living spaces below.
If the air distribution is in the attic space then consider insulating the rafters to move the distribution into the conditioned space.
Most updated central air conditioned homes have a new air conditioner split system meaning the ac is broken up into parts.