One such test is the plastic sheet test astm d4263.
Concrete moisture test using plastic sheet method.
Drop us a line in the comments below or give us a call at.
The plastic sheet method was developed by astm international and involves taping a plastic sheet to the surface of the concrete to create a vapor proof seal around the plastic.
It is important to understand why this testing method is unreliable for determining concrete slab moisture problems.
Tape along all four edges of the square with duct tape or other waterproof tape.
So it is suitable for the case where the application of coatings for concrete surface is planned.
To use this method astm d 4263 standard test method for indicating moisture in concrete by the plastic sheet method a plastic sheet is tightly taped to the concrete.
The sheet is left in place for 72 hours then a dewpoint hygrometer is used to test the level of moisture that is in the air under the sheet.
Some methods of concrete moisture testing use a simple qualitative approach.
Concrete moisture and vapor test methods 1.
After 72 hours a humidity reading is taken under the plastic with a dew point hygrometer.
1 2 the values stated in inch pound units are to be regarded as standard.
Firmly press the tape to create a moisture tight seal with the plastic and concrete.
This means no numbers or data just simple observation or eyeballing of the test location and testing materials for signs of excessive moisture.
Use as many squares as needed to test all the main areas that may get flooring.
This video discusses and demonstrates the plastic sheet method for measuring moisture in concrete.
The test shall be conducted prior to the use of coating.
Spread out each plastic square flat over a dry area of concrete.