City of los angeles standard retaining wall detail.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Retaining or slough wall 4 foot high or less 178 kb view.
Page 1 of 2 retaining or slough wall 4 0 high or less.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
The standard plans are divided into several series.
Each series contains several standard plans.
Acceptable engineering criteria for retaining wall design.
Concrete block units shall conform to astm c90.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
Concrete block units to have vertical continuity of the cells unobstructed.
City of los angeles electrical plan check correction list.
Back to standard plans main index.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Metal bin type retaining wall.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
Build safe well and fast with the city of los angeles department of building and safety.
Informational page for pre approved standard plans.
Multiple cover details for sanitary sewer manholes.
Alternative design procedures justified in a geotechnical report may also be approved.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
Reinforcing steel shall be deformed steel conforming to a s t m.
Soil lateral loads labc 1610 1 general.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Disabled access standard details notes for commercial buildings.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
Lap all steel 16.
San diego municipal code chapter 14 article 2.
City of los angeles electrical plan check correction list.